Error Code |
Meaning Of Error |
What This Means |
 |
Failure of the High Limit Sensor |
Replace OH/High Limit Sensor
Go To Sensors |
 |
Failure of the Temp Sensor |
Replace Temp Sensor
Go To Sensors |
 |
Lack of Water Flow or Failure of
Flow or Pressure Switch |
Remove filter and restart. If
returns, if you DO see water moving without pushing JET
button, failure of flow switch or pressure switch, whichever
your spa has. If you do NOT see water automatically moving
when you turn main power on, then likely the circ pump. Rare
occasions its the board. |
 |
Failure of Flow or Pressure
Switch |
Replace Flow or Pressure Switch.
Go To Switches |
 |
"Cool" condition exists. Temp 20
degrees or more below set temp. Spa is attempting to heat. |
Automatic; Do nothing. Will stop
when spa is heated. |
 |
Freeze Protection On |
Automatic; Do nothing. Spa will
turn on jet pumps to keep spa from freezing. Only panic if
spa isn't heating. |
 |
Water is Above 112 degrees. Spa
has turned on Low Speed pump in attempt to cool the spa |
Spa automatically tries to cool
spa. If water goes above accepted range, spa will shut down.
Typically this means the board has failed and leaving heater
on when it should not. If water and heater do not get hot
but the spa goes into OH, either the OH sensor or the board
has failed. |
 |
"Watchdog" mode |
Most common cause is failure of
the temp sensor. Replace. If that doesn't solve then likely
a board failure. See >Watchdog |
|
ONLY On LCD
Topsides: |
 |
Panel Sensors pressed to fast.
Temporary deactivating |
Slow down pushing buttons. |
 |
Circuit Board temp above normal.
Shuts down operation until the board cools |
Will reset when equipment area
cools. |
 |
Panel connection/operation to
board is faulty |
Secure connects or in rare
cases, either the board or topside has failed. |
 |
Failure of Temperature Sensor |
Replace Temp Sensor. |