Systematic Steps To Help Determine Failure |
|
Step |
What See |
Next |
| One |
Nothing works |
| a. Check breaker by
turning completely off and then on. On most
installations, must do this both at the main home panel
and a sub panel. |
| b. Next, check voltage
to spa with ACTUAL meter. Check voltage hot to hot. You
should have 220-240vac. If not, you have incoming power
failure; not the spa. |
| c. If proper voltage
to the spa, turn off power. Set meter to OHMS and check
all fuses. If fuses are fine, likely a board failure. |
|
|
Two |
Spa is running but no digital readout. |
| a. Do jet buttons
work? If so, likely the topside. Could be the board. |
| b. If digital is out
and buttons don't work, either a topside or board
failure. |
|
| Three |
Spa is running but
giving error code. |
See
Error Codes and Their Meaning |
|
Four |
Spa is running, no code, but spa is
not hot. |
| a. If everything works
but water is getting cold and no error, likely the
heater. To test you need a voltmeter. Turn off spa power
and set meter to OHMS. Place a probe on each heater
connection. You should have 10-15k ohm resistance. If
not, you have a bad heater. |
| b. If ohm check is
fine, change the voltmeter to read above 250vac. Turn on
spa. When the heater light or icon comes on, CAREFULLY
place a prove on each heater connection. You should have
220-240vac. If no, you have a bad board. |
|
| |
|
|
|
Summary: |
You must check incoming
power first and confirm actual voltage to the spa. I
have seen breakers partially fail and deliver 24vac to
the spa. The spa will not operate. So YOU say power is
there but in reality, it is not.
Once you know current is
correct, then either the above or the error codes will
help ID what is wrong. During business hours you can
contact LIVE CHAT or other
times, go to the Live Chat link and leave a message. |
|
|